Radio Gateway R-1261 is designed to provide interface between radio nets, digital automatic communication switchboard systems (DACSs) and LANs in stationary and combat communication systems; information exchange between counterpartners of radio nets and telephone users, as well as users of automated control systems.
R- 1261 operates in the following climatic conditions:
- temperature of ambient environment is in the range from 238 to 323K (from -350 to +500 C)
- relative humidity is not more than 98% under the temperature of 298K (250 C)
- air pressure is from 60 кPa to 113 кPа (from 450 to 850 mm.m.c).
Weight is not more 25 kg
Dimensions:
- Length – 490 mm;
- Width – 490 mm;
- Height – 300 mm.
Specifications
Radio Gateway R-1261 provides connection of:
- six VHF and HF tactical radios in simplex, half-duplex and duplex modes;
- six analog telephones;
- digital telephone set (ISDN BRI channel);
- PC at RS-232-interface;
- two external LANs at Ethernet 10 Base-T-interface;
- one ISDN BRI channel;
- two analog trunks from DACS.
Radio Gateway R-1261 provides message exchange of:
- radiotelephony and data transfer between counterpartners of different radio nets;
- radiotelephony between counterpartners of radio nets and analog telephone users;
- radiotelephony and data transfer between counterpartners of radio nets and digital ISDN telephone users;
- radiotelephony and data transfer between counterpartners of radio nets and terminal equipment (digital telephone set and PC), connected directly to the radio gateway.
Radio Gateway R-1261 provides automatic connection and data exchange of:
- counterpartners of different radio nets with radio stations, connected to the radio gateway;
- counterpartners of radio nets with users of ATS ;
- users of ATS with counterpartners of radio nets;
- counterpartners of radio nets with users of LAN workstations;
- users of LAN workstations with counterpartners of radio nets;
- counterpartners of radio nets with radio gateway operator;
- radio gateway operator with counterpartners of radio nets;
- users of ATS (analog and ISDN) with radio gateway operator;
- radio gateway operator with users of ATS (analog and ISDN);
- radio gateway operator with users of LAN workstations;
- users of LAN workstations with radio gateway operator.
Power supply:
Power supplying is provided by direct current 27 V with extreme voltage deviation from 18 to 36V.